Mitsubishi Electric MLP-444WU Manual De Instalación página 56

Ocultar thumbs Ver también para MLP-444WU:
Idiomas disponibles

Idiomas disponibles

1-4. INSTALLATION DIAGRAM
E
Units should be installed by licensed contractor according to local code
requirements.
IMPORTANT NOTES
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
Service space
• The dimensions of ceiling opening can be regulated within the range shown
in following diagram; so center the main unit against the opening of ceiling,
ensuring that the respective opposite sides on all sides of the clearance
between them becomes identical.
E
Ceiling surface
ACCESSORIES
Check the following parts before installation.
Alkaline battery (AAA) for
Drain hose (with insulation)
Special washer (with cushion, 4 pcs)
Installation template
Fixing screw for
M5 × 30 mm
Band
Fixing screw for
4 × 16 mm
Remote controller
Remote controller holder
Fixing screw for
3.5 × 16 mm (Black)
En-3
L
K
A
B
J
H
M
P
N
E
Grille
Ceiling surface
PARTS TO BE PROVIDED AT YOUR SITE
Refrigerant pipe
A
2
Drain pipe (O.D. 1 in. (26 mm))
B
1
Installation tools (See 1-3)
C
8
Indoor/outdoor unit connecting wire*
D
1
Suspension bolt (W 3/8)
E
4
Nut with flange (W 3/8)
F
1
Nut (W 3/8)
G
2
Insulating material for
1
(Heat resistant foamed polyethylene,
H
1
specific gravity 0.045, thickness more than
9/16 in. (14 mm))
2
Insulating material for
(Foamed polyethylene, specific gravity
J
0.03, thickness more than 3/8 in. (10 mm))
Be sure to use wall hole sleeve
to prevent indoor/outdoor
K
connecting wire
from contacting metal parts in the wall and to
D
prevent damage by rodents in case the wall is hollow.
Wall hole cover
Indoor unit
Seal the wall hole
gap with putty
Wall hole
Fix the pipe to wall
sleeve
K
with pipe fixing
band
Cut off the
Pipe fixing band
extra length.
Fixing screw
After the leak test, apply insulating material tightly so that there
is no gap.
When the piping is to be attached to a wall containing metals (tin
plated) or metal netting, use a chemically treated wooden piece
13/16 in. (20 mm) or thicker between the wall and the piping or wrap
7 to 8 turns of insulation vinyl tape around the piping.
To use existing piping, perform COOL operation for 30 minutes and
pump down before removing the old air conditioner. Remake flare
according to the dimension for new refrigerant.
Air outlet
Air inlet
Where airflow
is not blocked.
1
K
1
L
1
M
1
N
4
P
8
Q
4
* Note:
A
Place indoor/outdoor unit connecting wire
1
D
antenna wire.
B
1
L
.
L
.
M
M
N
inch (mm)
Ceiling surface
7-7/8 (200)
or more
Wall hole sleeve
1
Parts for mending wall hole
1
(putty, cover)
Pipe fixing band
2 to 7
2 to 7
Fixing screw for
M
Piping tape
1 to 5
Protective tape
1
at least 3 ft. (1 m) away from the TV
loading