EINHELL GE-DP 7935 N-A LL ECO Manual De Instrucciones Original página 21

Bomba de agua sucia
Ocultar thumbs Ver también para GE-DP 7935 N-A LL ECO:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92
11. Troubleshooting guide
Faults
The equipment does
not start
The equipment does not
pump
The equipment does not
cut out
Insuffi cient pumping
rate
The equipment switches
off after briefl y running
Cause
- Power supply not connected
- Observe the autostart level
- Intake sieve clogged
- Discharge hose kinked
- Observe the autostart level
- Intake sieve clogged
- Performance reduced due to
heavily contaminated and abra-
sive water impurities
- Motor circuit-breaker switches
the equipment off due to exces-
sive water contamination
- Water temperature too high; mo-
tor circuit-breaker switches the
equipment off
GB
- Check power supply
- Turn the autostart level to the cor-
rect position
- Clean intake sieve with water jet
- Unkink the hose
- Turn the autostart level to the cor-
rect position
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
- 21 -
Remedy
loading

Este manual también es adecuado para:

41.714.65