EINHELL GE-DP 7935 N-A LL ECO Manual De Instrucciones Original página 19

Bomba de agua sucia
Ocultar thumbs Ver también para GE-DP 7935 N-A LL ECO:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92
6. Operation
6.1 Using for the fi rst time
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up secu-
rely.
Check that the discharge line is fitted correct-
ly.
Make sure that the electrical connection is
230 V ~ 50 Hz.
Check that the electrical socket-outlet is in
good working order.
Make sure that no moisture or water can ever
reach the power connection.
Take care that the equipment does not run
dry.
6.2 Shallow suction mode and dirty water
mode (Fig. 4)
6.2.1 Shallow suction mode (Fig. 4a)
Turn the equipment counter-clockwise and
press it to the bottom.
In shallow suction mode, water can be su-
cked up down to a level of 1 mm.
Only clear water can be pumped in shallow
suction mode.
6.2.2 Dirty water mode (Fig. 4b)
In dirty water mode the equipment can be set for
three diff erent sizes (15/25/35 mm).
Turn the equipment clockwise and pull it
upwards by the handle to the setting that you
require. Make sure that the locking screws
latch in place (B).
6.3 Operating mode (Fig. 5)
The equipment can be operated in manual mode
and in autostart mode.
6.3.1 Manual mode: Switch (C) in "ON" posi-
tion
In ON mode the equipment will run continuously.
6.3.2 Autostart mode
In autostart mode you can set 3 activation heights
at switch (C).
The activation heights will change as soon as you
switch between shallow suction mode and dirty
water mode.
GB
Shallow suction mode
Autostart level 1: Activation height 15 mm
Autostart level 2: Activation height 100 mm
Autostart level 3: Activation height 150 mm
Dirty water mode (example: 35 mm)
Autostart level 1: Activation height 50 mm
Autostart level 2: Activation height 130 mm
Autostart level 3: Activation height 180 mm
If the intake cage is adjusted to 15/25 mm,
the activation heights will change accordin-
gly.
6.4 How the integrated fl oat switch works
Application 1:
In On mode the equipment will run continuously
and the water can be sucked up in shallow suc-
tion mode down to a level of 1 mm. In dirty water
mode (e.g. 35 mm), the water can be sucked up
down to a level of 40 mm.
To prevent dry running, this operating mode
is allowed only under supervision.
The equipment must be switched off (pull out the
power plug) as soon as no more water is emitted
from the discharge line.
Please note:
For the equipment to suck up water in ON mode
there must be following water level.
Shallow suction mode: 15 mm
Dirty water mode: 50 mm (example: 35 mm)
Application 2:
The pump is used in autostart mode when there
is a rising level of water. When the preset auto-
start level is reached, the pump will start automa-
tically. Regardless of the preset autostart level, in
shallow suction mode the pump will pump off the
water down to a level of 1 mm, will then continue
to run for approximately another 15 seconds, and
will then switch off automatically. In dirty water
mode (35 mm) the pump will switch off at 40 mm.
Please note:
Switching off automatically after 15 seconds pre-
vents the pump from running without water for a
- 19 -
loading

Este manual también es adecuado para:

41.714.65