TROUBLE
1.Fan will not start.
1. Loose electrical connections in the
ceiling cover.
2.Fan sounds noisy.
1. Blades not attached to fan.
2. Wire connectors inside switch
housing cover are rattling.
3. Screws holding flange/blades
3.Fan wobbles
to motor are loose.
excessively.
1. Setscrews in motor coupler are
loose.
2. Setscrew in hanger ball/downrod
assembly is loose.
3. Screws securing fan blades to
motor are loose.
4. Hanger bracket and/or ceiling outlet
box is not securely fastened.
TROUBLESHOOTING REMOTE CONTROL
Fan/Light Fails to Operate
• Check that the speed switch on the fan is set to HIGH
speed.
• Check that the light switch is on.
• Check that the battery is good (red indicator light should
light when any button is pressed).
• Check that the receiver is wired properly.
• Check that both code switches are set in the same
position.
All manuals and user guides at all-guides.com

15. Troubleshooting

WARNING
!
PROBABLE CAUSE
32
SUGGESTED REMEDY
1. Check the electrical connections at the ceiling
cover.
WARNING
!
Make sure main power is turned OFF.
1. Attach blades to fan before operating.
2. Check to make sure wire connectors in switch
housing cover are not rattling against each other
or against the interior wall of the switch housing
cover.
WARNING
!
Make sure main power is turned OFF.
3. Tighten screws securely.
1. Tighten both setscrews securely in the motor
coupler.
2. Tighten the setscrew in the hanger ball/downrod
assembly.
3. Check to be sure screws which attach the fan
blades to the motor are tight.
4. Tighten the hanger bracket screws to the outlet
box, and/or secure outlet box.
Short Range
• If the remote control operates the fan when close to it,
but does not operate it at a distance of 30 feet, try
placing the antenna wire outside of the ceiling cover.