FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start. 1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan.
3. Fan/Light remote control is OFF.
2. Fan sounds
1. Blades not attached to fan.
noisy.
2. Screws securing fan blades to motor
are loose.
3. Fan wobbles
1. Screws securing fan blades to motor
excessively.
are loose.
2. Fan blades are not seated properly.
3. Fan blades out of balance.
4. Light fixture will
1. Loose electrical connectors.
not illuminate.
2. Remote control battery is weak.
13. Energy Efficient Use of Ceiling Fans
Ceiling fan performance and energy savings rely heavily on
the proper installation and use of the ceiling fan. Here are a
few tips to ensure quality and product performance.
Choosing the Appropriate Mounting Location. Ceiling
fans should be installed, or mounted, in the middle of the
room and at least 7 feet above the floor and 18 inches from
the walls. If ceiling height allows, install the fan 8 - 9 feet
above the floor for optimal airflow. Consult your Emerson
Retailer for optional mounting accessories.
Using the Ceiling Fan Year Round. In the summer, use the
ceiling fan in the counter-clockwise direction. The airflow
produced by the ceiling fan creates a wind-chill effect, making

12. Troubleshooting

WARNING
!
PROBABLE CAUSE
you "feel" cooler. Select a fan speed that provides a
comfortable breeze, lower speeds consume less energy. In
the winter, reverse the motor and operate the ceiling fan at
low speed in the clockwise direction. This produces a gentle
updraft, which forces warm air near the ceiling down into the
occupied space. Remember to adjust your thermostat when
using your ceiling fan - additional energy and dollar savings
could be realized with this simple step!
Turn Off When Not in the Room. Ceiling fans cool people,
not rooms. If the room is unoccupied, turn off the ceiling fan to
save energy.
22
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
WARNING
!
Make sure main power is turned OFF.
2. Check line power connections to fan.
3. Turn ON Fan/Light remote control.
1. Attach blades to fan before operating.
2. Check to make sure the screws which attach the
blades to the motor are tight.
WARNING
!
Make sure main power is turned OFF.
1. Check to be sure screws which attach the fan blade
to the motor are tight.
2. Check to be sure that the screws securing the fan
blades seat firmly.
3. Interchanging an adjacent (side by-side) blade pair can
redistribute the weight and result in smoother operation.
Or use supplied balancing kit to balance blades.
1. Shut off the branch circuit electricity at the fuse box or
breaker panel and check the receiver electrical connectors
for proper installation.
2. Replace the AAA remote batteries.