Ferroli EGEA TECH 200 HT Manual De Uso, Instalación Y Mantenimiento página 173

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
EGEA TECH
Damper "A"
open
fig. 56- Example of installation in the winter period
8.6.4 Aeraulic connections prohibited
Water heater that draws the air from a heated room.
• Connection to the VMC.
• Connection on the attic.
• Connection to the external air in the intake and expulsion of the fresh air
inside.
• Connection to a Canadian well.
• Water heater installed in a room containing a natural draft boiler and
channeled to the outside for the release of air only
• Aeraulic connection of the appliance to a tumble dryer.
• Installation in dusty rooms.
• Withdrawal of air containing solvents or explosive materials.
• Connection to hoods that evacuate greasy or polluted air.
• Installation in a freezing room.
• Objects placed above the water heater.
200 HT - 260 HT
Mandatory air
inlet D.160 mm
Damper "B"
closed
Internal
compartment
cod. 3540000420 - Rev. 03 - 09/2023
8.7
Hydraulic connections
Connect the cold water supply line and the outlet line to the
appropriate connection points (fig. 57).
The table below gives the characteristics of the connection
points.
Ref.
Function
1
Cold water inlet
4
Recirculation
5
Hot water outlet
6
Condensate drain
B
Magnesium anode
For the correct operation of the
device, the inlet water pressure
must be:
ATTENTION
- maximum 0.7 MPa (7 bar);
- minimum 0.15 MPa (1.5 bar).
Model 200 l / 260 l
1"G
3/4"G
1"G
1/2"G
-
fig. 57
EN
173
loading