Installation example:
4
AIR TOWARDS
INDOOR
DIRTY AIR EXTRACTED
FROM BATHROOM
2100mm
7
Drainage connection
The condensate drain can be made by connecting two flexible pipes with an internal diameter of approximately
16 mm to the drains. To prevent the formation of air bubbles, it is necessary to create a siphon with the tube that
comes out of the drain identified with number 1 on the appliance, as indicated in figg. 5 and 7.
Diagonally cut the tube termination.
The configuration illustrated in figure 6 should be absolutely avoided.
Note: It is necessary to make the siphon, respecting the dimensions indicated in fig.8 otherwise the regular
operation of the appliance is not guaranteed.
Condensate can also be drained off through the waste plumbing system of the building.
5
1
6
2
ENGLISH
FRESH AIR INLET
AIR EXHAUST
TOWARDS
OUTDOOR
2
1
39