DESCRIPTION AND USE

Noise attenuators for circular ducts manufactured
from galvanised steel. Circular spigot connections
are available in standard diameters of 100-125-150-
160-160/05-200-250-315-355-400 mm (DIN 24145).
CAUTIONS - PRECAUTIONS
!

Cautions:

• Do not use the appliance for any application other
than that stated in this booklet.
• After removing the appliance from its packaging,
ensure that it is complete and undamaged. If in
doubt contact a professionally qualified electrician
!

Precautions:

• Do not make any modifications of any kind to your
appliance.
• The appliance must not be exposed to atmospheric
conditions (rain, direct sunlight, etc.).
• Install the appliance in accordance with the
manufacturer's instructions.
• Do not place objects on the appliance.
• Regularly inspect the appliance for visible defects.
If any faults are found, do not operate the appliance
but contact Vortice* immediately.
• If the appliance does not function correctly or
develops a fault, contact Vortice* immediately and
ensure that only genuine original Vortice spares are
used for any repairs.
• Should the appliance be dropped or suffer a heavy
blow, have it checked immediately by Vortice*.
* (or an authorised Service Centre if you are outside the
UK-Ireland territory)
Notes
• The flow of air or fumes injected into the

FRAME

Internal tube in drilled aluminium sheet spiral with a
thickness of 0.1 mm.
Containment heads in PE film.
Insulation in basalt wool with a thickness of 40 mm.
Heat resistance R = 1.00 m
External tube in aluminium sheet spiral with a
thickness of 0.1 mm.

CONNECTION / ASSEMBLY

The appliance is connected to the system by means
of a forced insertion on two cylindrical fittings in
galvanised steel with circular rubber built-in "T" seals.
11/05/2007
17.28
Pagina 7
this symbol indicates caution messages aimed at avoiding personal injury
to the user
this symbol indicates precautions which should be taken to avoid damage
to the product
2
k/W.
or Vortice*. Do not leave packaging within the reach
of children or infirm persons.
• Do not sit on or place objects on the appliance.
• Have the filters of the noise attenuator serviced and
replaced only by suitably qualified personnel.
appliance must be clean (that is free from
grease, smoke, chemical or corrosive
substances or explosive and inflammable
mixtures).
• The NA noise attenuator must be installed on a
ventilation line, upstream or downstream from
the fan, and always upstream from the air heater
(AH), if present, and downstream from the air
filter (AF). To install the air attenuator, it is
sufficient to insert it into the tube (Fig. A).
• The appliance is designed for use in ventilation
systems that specifically require a low overall
noise.
• The appliance is designed to operate indoors
with temperatures ranging from 30 °C to 60 °C,
to convey clean air. It is not suitable for use for
air laden with dirt, grease, smoke, chemical and
corrosive agents.
• It is necessary to make sure that no condensate
circulates or accumulates within the tubes.
• The appliance can be installed by inserting it
into ducting with appropriate dimensions.
• Pressure losses should be calculated in
accordance with the diagram on page 29.