English
Owner´s manual
•
Compressor runs
continuously
Compressor vibrates
Lower than usual air
flow rate
ATTENTION: Do not make any modifications to the machine that may damage its operation. Any
alterations or modifications made will invalidate the product warranty.
If your device continues to give errors or presents any other type of problem, please contact our
technical service so that our team can advise you and solve the problem.
9. TECHNICAL DATA
MODEL
Displacement
Voltage
Engine type
Power
Working speed (rpm)
Tank capacity
Air flow rate (l/min)
Nominal pressure (bar- PSI)
Max. pressure (bar- PSI)
Noise level
Weight
Defective pressure switch.
Excessive air demand.
Air leakage.
Loose mounting screws
Broken inlet valves.
Dirty suction filter.
Leaking connections.
GY08248SOF
230V / 50Hz
0,8 HP / 0,6 Kw
1450 rpm
110 l/min aprox.
73 dB
20,6 kg
Replace the switch.
Use tools sized to the flow rate that the
compressor can deliver.
Check all connections with a soap and
water solution to see where the leak
can be found.
Tighten the screws
Have the unit repaired by an authorized
service representative.
Clean or replace the suction filter.
Tighten connections.
GY 08248SOFS
GY 08248SOFH
Single cylinder
110V / 60Hz
Brushless
1 HP / 0,75 Kw
1 HP / 0,75 Kw
1750 rpm
24 L
130 l/min aprox.
130 l/min aprox.
6 bar - 85 PSI
8 bar - 115 PSI
78 dB
21 kg
220V / 60Hz
1750 rpm
78 dB
21 kg
33