Owner´s manual
End of operation / Storage
1. Once your compressor is off and has cooled down, unplug the power cord from the outlet and wrap it
around the handle to prevent damage when not in use.
2. With safety goggles on and taking care that air is directed to your face, empty the air reservoir by
pulling the ring on the safety valve.
3. Empty the condensation from the reservoir by opening the drain valve at the bottom of the reservoir.
4. The air hose should be disconnected from the compressor and the open end should hang down to
drain the condensation.
5. The compressor and hose should be stored in a cool, dry place.
On / Off
ON
Air pressure settings
1. With the pressure regulator you can set the desired pressure (0-6 bar). Pay attention to the nameplate of
the pneumatic tool to be connected.
2. The reservoir pressure can be checked on the gauge provided.
3. All compressors are equipped with a pressure regulator. By operating the knob with the tap open, turn
the regulator clockwise to increase the pressure and counterclockwise to decrease it, the air pressure
can be regulated to optimize the use of pneumatic tools.
4. The set value can be checked on the pressure gauge.
ATTENTION:
Check that the air consumption and maximum working pressure of the pneumatic tool to be used are
compatible with the pressure set on the pressure regulator and with the amount of air supplied by the
compressor.
Releasing overpressure
Switch off the compressor.
Use the overpressure with an idle pneumatic tool.
Condensate water drainage
Condensation water accumulates at the bottom of the boiler. You should periodically drain the tank to
protect it from corrosion and not restrict its capacity.
WARNING: Condensation water should only be drained when the boiler is NOT under pressure.
28
OFF
(adjusting pressure)
WARNING:
Always disconnect the plug and drain the tank
once you have completed your work.
Always wait at least 10 seconds after the
compressor shuts off before restarting the
compressor.