8. TROUBLESHOOTING
Problem
Compressor does not
start.
1. Remove the filter housing cover.
2. Remove the filter, in case it is clogged.
3. Replace the filter.
ATTENTION: Paper filters cannot be washed.
4. Replace the cover.
Possible cause
The unit is plugged into the extension
cord.
There is no electric current.
Fuse blown.
Open circuit breaker.
Thermal overload.
Defective pressure switch.
Motor winding shorted or open.
Solution
Remove the extension cord or use a
heavier gauge extension cord.
Check that it is properly plugged in /
Check fuse - circuit breaker or motor
overload.
Replace blown fuse.
Press again.
Unplug and allow motor to cool before
attempting to restart.
Replace circuit breaker.
Replace motor.