BUTTONS
AUDIO/VIDEO MODULE
•
Button: select the button to program, referring to the images
•
Function: this option is used to assign a different action to each module button
◊
None: no action (default)
◊
Light-me: this option is used to activate the LIGHT-ME function for the selected button
◊
Audio call: when the button is pressed, an audio call is made to the address entered in the "Address"
field (from 1 to 240). The "Number of calls" field also appears, in which you can select the number of
calls to make to the address entered in the "Address" field (System settings or from 1 to 10)
◊
Video call: when the button is pressed, a video call is made to the address entered in the "Address"
field (from 1 to 240). The "Number of calls" field also appears, in which you can select the number of
calls to make to the address entered in the "Address" field (System settings or from 1 to 10)
◊
Local output control: when the button is pressed, the output set in the "Output" field is activated (SE
output for the module or Relay output for the module)
◊
Actuator control: when the button is pressed, the actuator with the address entered in the "Address"
field is activated
◊
Control on Ultra bus (UDB): activates the relay on the Module keypad specified in the "Type" field
(Output: Relay 1 or Relay 2)
BUTTON MODULE TYPE
•
Functions: select the button module model, UT9200 (default) or 3063U
MODULE 1... MODULE 31
•
Button: select the button to program, referring to the images
•
Function: this option is used to assign a different action to each module button
◊
None: no action (default)
◊
Audio call: when the button is pressed, an audio call is made to the address entered in the "Address"
field (from 1 to 240). The "Number of calls" field also appears, in which you can select the number of
calls to make to the address entered in the "Address" field (System settings or from 1 to 10)
◊
Video call: when the button is pressed, a video call is made to the address entered in the "Address"
field (from 1 to 240). The "Number of calls" field also appears, in which you can select the number of
calls to make to the address entered in the "Address" field (System settings or from 1 to 10)
◊
Local output control: when the button is pressed, the output set in the "Output" field is activated (SE
output for the module or Relay output for the module)
◊
Actuator control: when the button is pressed, the actuator with the address entered in the "Address"
field is activated
◊
Control on Ultra bus (UDB): activates the relay on the Module keypad specified in the "Type" field
(Output: Relay 1 or Relay 2)
OUTPUTS
SE OUTPUT
•
Function: select the command which activates the SE output for the audio/video module
◊
Lock-release: every lock-release command activates the output
◊
Actuator control: every actuator command with the address set in the "Address sent to external unit"
field activates the output
◊
Call sent: every call sent activates the output
•
Activation
◊
Local output control (non-editable)
•
Output
◊
SE (non-editable)
•
Enable tones: a confirmation tone is emitted when the output is activated for the time period set in the
"Activation time (sec.)" field
12