aquatechnik BST 32 PLUS Instrucciones De Uso página 39

Idiomas disponibles
  • ES

Idiomas disponibles

WARNING
forcibly jam button (B) with cable ties or any other clamping means. This button is a safety, dead
man's switch. Powering it off immediately upon release ensures safety for the operator.
STEPS FOR CREATING FLARES WITH REUSABLE EXPANDER
1. Fit the desired working diameter head onto the Pipe Flaring Machine BST 32 PLUS.
WARNING
itself in this state at the end of a flaring cycle. The Pipe Flaring Machine BST 32 PLUS can,
however, be brought to its resting position at any time by using the emergency return device
(C, fig.2a-2b).
fig. 2a
2. Insert the reusable expander (F) with the flange facing the Pipe Flaring Machine into the
removable head (E) as in figure 3. Screw on the ring nut (G).
Screw the header onto the Pipe Flaring Machine BST 32 PLUS, then insert the extractor (H)
until it clicks into place (fig. 4).
3. Cut the pipe with care, then insert the cap.
4. Insert the extractor (H) into the pipe, up to the stop on the flange of the reusable expander (F).
CAUTION
CORRECT
ON/OFF SETTING, BUTTON B fig.1
The advance button (B) can and should only operate with continuous
pressure of the operator's finger. IT IS STRICTLY FORBIDDEN to
To carry out this operation, the device must be in the resting posi-
tion. The Pipe Flaring Machine BST 32 PLUS automatically positions
fig. 3
Caution: the pipe must be aligned on axis and parallel to the extrac-
tor (H, fig. 5).
fig. 2b
fig. 4
INCORRECT
EN
fig. 5
39