Charging Battery Pack - aquatechnik BST 32 PLUS Instrucciones De Uso

Idiomas disponibles
  • ES

Idiomas disponibles

IMAGES AND INFORMATION OBTAINED FROM THE ORIGINAL METABO MANUAL (170300020-0321)
6. Initial Operation
Before commissioning, check that the rated mains voltage and mains frequency stated
on the type plate match your power supply.
Devices like these that generate direct current caninfluence simple earth leakage protection
devices. Use a type F or better, with a release current of max. 30 mA.
Before commissioning the charger, ensure that the air slots are free. Minimum distance
to other objects is 5 cm!
6.1 Self-test
Plug in.
The warning display (4) and the operating indicator (3) light up one after the other for approx.
1 second and the installed fan runs for approx. 5 seconds.
7. Use

7.1 Charging battery pack

Push the battery pack completely to the stop on the sliding seat (2).
The operating indicator (3) flashes.
Note: to have the charge level displayed on Li-ion battery packs, first take the battery pack
out of the charger and then press the button on the battery pack.
7.2 Conservation charge
Once the charging process has finished, the battery charger automatically switches to con-
servation mode.
The battery pack can remain in the battery charger and is therefore always ready for use.
The operating display (3) lights up continuously.
8. Faults
8.1 Warning display (4) lights up continuously
Battery pack is not charged.
Excessive/insufficient temperature.
When the temperature of the battery pack is between 0°C and 50°C, the charging process
begins automatically.
8.2 Warning display (4) flashes
-
Battery pack is defective. Remove the battery pack immediately from the charger.
-
The battery pack was not pushed correctly onto the sliding seat (2). See chapter 7.1.
BATTERY CHARGER
EN
35
loading