go out. In addition, unplug the device from the power outlet. If you
do not use the device for a long period of time, immediately empty
the device of the cooling solution by unscrewing the valve tap
located on the back of the device and draining the solution.
• The device should be cleaned and dried after operation and
further non-use.
3.3.4
Operation programming
• Press the "Set" button on the control panel to display the
temperature set on the device, and if necessary, use the ˄/˅
buttons to change its value.
• In turn, by pressing and holding down the "Set" button for 6
seconds, you can enter the parameter setting menu. Then the
option to change the temperature is inactive and pressing the
"Set" button again to change between setting options: HL-LS-HS-
PL-CA-d:
•
the button on the "HC" option allows you to select heating ("H")
or cooling ("C") functions - select the appropriate function with the
˄/˅ buttons.
EN
a. Temperature set
b. Current temperature
c.
Heating indicator light
d. Cooling light
e. Error light
- pressing and holding down