L6
Open
Partially
L7
Mainte-
nance
warning
L8
List of
malfun-
ctions
Note: "
" represents the factory setting
All the parameters can be adjusted as required without any contraindication; only the adjustment of the "motor force" could require special care:
• Do not use high force values to compensate for points of abnormal friction on the leaf. Excessive force can compromise the operation of the safety system or damage the leaf.
• If the "motor force" control is used to assist the impact force reduction system, measure the force again after each adjustment in compliance with EN standard 12445.
• Wear and weather conditions may affect the movement of the gate, therefore periodic force re-adjustments may be necessary.
01. Press the key "Set" and hold it down (approx. 3 s);
02. Release the "Set" key when L1 LED starts flashing;
03. Press the key "▲" or "▼" to move the flashing LED onto the input LED representing the parameter which is to be changed;
04. Press the key "Set" and hold it down during step 5 and 6;
05. Wait approx. 3 seconds, after which the LED representing the current level of the parameter which is to be modified will light up;
06. Press key "▲" or "▼" to move the LED representing the parameter value;
07. Release the key "Set";
08. Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
Note – Points 3 to 7 can be repeated during the same programming phase in order to set other parameters
Programming examples: level one and level two
Level one: The sequence to follow in order to change the factory settings of the functions for activating "Automatic Closing" (L1) and "Always close"
(L3) have been included as examples:
01. Press the key Set and hold it down (approx. 3 s);
02. Release the Set key when L1 LED starts flashing;
03. Press the Set key once to change the state of the function associated with L1 (Automatic Closing).
LED L1 will now flash with long flashes;
04. Press the ▼ key twice to move the flashing LED to LED L3;
05. Press the Set key once to change the state of the function associated with L3 (Always Close).
LED L3 will now flash with long flashes;
06. Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
Once these operations have been completed, LEDs L1 and L3 must remain on to indicate that the "Automatic Closing" and the "Always Close" functions
are active.
L1
0,5 mt
L2
1 mt
L3
1,5 mt
L4
2 mt
L5
2,5 mt
L6
3 mt
L7
3,4 mt
L8
4 mt
L1
Automatic (depending on the severity of the manoeuvre)
L2
1000
L3
2000
L4
4000
L5
7000
L6
10000
L7
15000
L8
20000
L1
1
a
manoeuvre result
L2
2
a
manoeuvre result
L3
3
a
manoeuvre result
L4
4
a
manoeuvre result
L5
5
manoeuvre result
a
L6
6
a
manoeuvre result
L7
7
a
manoeuvre result
L8
8
a
manoeuvre result
TABLE 8 - Changing the adjustable parameters
Adjusts the measurement of the par-
tial opening. Partial opening can be
controlled with the 2nd radio com-
mand or with "CLOSE", if the "Close"
function is present, this becomes
"Open partially".
Adjusts the number of manoeuvres
after which it signals the maintenan-
ce request of the automation (see
paragraph "Maintenance warning").
The type of defect that has occurred
in the last 8 manoeuvres can be
established (see paragraph "9.2 Mal-
functions archive").
SET
3 s
L1
SET
or
SET
or
SET
10 s
SET
3 s
L1
SET
SET
L1
L3
SET
L3
10 s
English – 9