EN
CORRECTION OF MALFUNCTIONS
14
CORRECTION OF MALFUNCTIONS
MALFUNCTION
The unit will not start
No coating material emerges
from the nozzle
Coating material drips from the
nozzle
Atomisation too coarse
Spray jet pulsates
Coating material causes "paint
tears
Excessive paint mist (overspray)
Paint in the ventilating hose
20
CAUSE
•
No mains voltage
•
Device overheated
•
Nozzle clogged
•
Material volume setting too low
•
Paint container seal damaged
•
No pressure build-up in container
•
Container empty
•
Ventilation hose loose/damaged
•
Feed tube loose
•
Feed tube / feed tube filter clogged
•
Air vent on feed tube blocked
•
Diaphragm stuck
•
Air cap, nozzle or needle soiled
•
Nozzle worn
•
Needle worn or damaged
•
Material volume too large
•
Nozzle contaminated
•
Viscosity of coating material too high
•
Too little pressure build-up in
container
•
Air filter heavily soiled
•
Amount of air too low
•
Air hose damaged
•
Coating material in container running
out
•
Air filter heavily soiled
•
Feed tube loose
•
Feed tube / feed tube filter clogged
•
Too much coating material applied
•
Distance too small
•
Incorrect spray nozzle set
•
Distance to the object too large
•
Too much coating material applied
•
Amount of air too high
•
Coating substance over-diluted
•
Incorrect spray nozzle set
•
Diaphragm soiled
•
Diaphragm defective
FineCoat 9700
REMEDY
•
Check
•
Unplug the power plug, let the device cool
down approx. 30 minutes, do not bend the
hose, check the air filter, do not cover the intake
slots
•
Clean
•
Increase volume
•
Replace
•
Tighten container
•
Refill
•
Insert or replace
•
Insert
•
Clean
•
Clean
•
Remove and clean (see section 13.2)
•
Clean
•
Change
•
Replace the needle (see section 3.1)
•
Reduce volume
•
Clean
•
Dilute further
•
Tighten container
•
Change (see section 13.1)
•
Increase volume
•
Check and replace if necessary
•
Refill
•
Change (see section 13.1)
•
Insert
•
Clean
•
Reduce volume
•
Increase distance
•
Use a different spray nozzle set
•
Reduce distance
•
Reduce volume
•
Reduce volume
•
Reduce degree of dilution
•
Use a different spray nozzle set
•
Clean the diaphragm (see section 13.2)
•
Replace the diaphragm (see section 13.2)