Porter Cable C5100 Manual De Instrucciones página 18

Idiomas disponibles

Idiomas disponibles

To Replace Regulator
1.
Release all air pressure from air tank. See
"To Drain Tank" in the Maintenance
section.
2.
Unplug outfit.
3.
Using an adjustable wrench remove the
outlet pressure gauge and quick connect
from the regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the nipple on
the standpipe.
6.
Assemble the regulator and orient as
shown.
NOTE: Arrow indicates flow of air. Make sure it is
pointing in the direction of air flow.
7.
Reapply pipe sealant to outlet pressure gauge
and quick connect.
8.
Reassemble outlet pressure gauge and quick connect. Orient outlet
pressure gauge to read correctly. Tighten connect with wrench.
18- ENG
loading

Este manual también es adecuado para:

C5100-ca