Jocel JAT011893 Manual De Instrucciones página 42

Idiomas disponibles

Idiomas disponibles

Problem:
Condition:
Control knob is not in Maximum
position (big flame).
LPG cylinder valve is closed /
Empty.
Blockage in the injector.
Burner won't
Air in the gas circuit.
light
Low gas pressure.
Igniter fails.
Dirty build up around burner.
Low flames or not full running
Burner won't
around the burner.
stay lit
Thermocouple is not operating
correctly.
Low Gas pressure.
Outdoor temperature is greater
than 5C and LPG cylinder is less
Burner flame
than 25% full.
is low
Note: Do not
Gas pipe is bent or kinked.
operate
appliance
Control knob is fully Maximum
below 5 ˚C
position (big flame).
Carbon build-
Dirty or film on burner.
up
Flash back
(flame inside
Burner ports are blocked.
burner)
Thick black
Blockage in the burner.
smoke
If you cannot solve trouble according to one of the mentioned solutions, please contact
technical assistance.
Solution suggested:
Turn control knob in Maximum position (big flame).
Open the valve/Replace LPG cylinder with a new
one.
Clean or replace injector.
Open gas line and bleed it (pressing control knob
in) for not over 1 minute or until you smell gas.
Replace LPG cylinder with a new one.
Use match to light burner; change battery or obtain
new igniter and replace
Clean dirty around the burner.
Flame spreader holes partially closed; clean the
burner.
Replace thermocouple (FSD).
Replace LPG cylinder with a new one.
Replace LPG cylinder with a new one.
Straighten hose and perform leakage test on gas
pipe.
Turn control knob to "OFF" position, let cool to
room temperature and check burner and orifices
for blockage.
Clean burner.
Switch OFF the appliance. Close LPG cylinder
valve. Wait 2 minutes, following the ignition
procedure. Ignite burner. If problem continuous,
switch-off. Contact your dealer.
Turn control knob to "OFF" position, let the
appliance to cool at room temperature and remove
blockage and clean burner inside and outside.
42
it.
loading