9. In case of accidental break down of the flame (for wind or other reasons), FSD will shut-off gas
supply automatically (FSD = Flame Safety Device) not over 60 seconds.
Note: The burner may be noisy when initially turned on.
If you experience any ignition problem consult the following "Troubleshooting".
TO TURN "OFF" THE APPLIANCE
1. Turn appliance control knob clockwise up to "OFF" position.
2. Turn the LPG cylinder valve to the "OFF" position.
3. Allow the appliance to cool before moving it (at least 30 minutes).
RE-LIGHTING
1. Turn control knob to "OFF" position.
2. Wait at least 5 minutes, to let gas dissipate, before attempting burner re-light.
3. Repeat the "Lighting" steps.
LEAKAGE TESTING
Never check for gas leakages with a flame or while smoking.
This appliance needs to be periodically checked for leakages
and an immediate check is required if the smell of gas is
detected.
• Make a soap solution using 1 part of liquid dish-washing soap
to 3 parts water. The soap solution can be applied with a soap
bottle, brush, or rag to the leakage tested points shown in the
figure beside.
• The valve of the LPG cylinder should be in the "OFF" position
at this point of the leakage test. Once the soapy solution is
applied to the gas connections, the valve of the LPG cylinder
needs to be turned to the "ON" position.
• Soap bubbles will begin to form in the soapy solution if any
leakage is present.
• In the event of gas leakage, the appliance shall not be used
or if alight, the gas supply shall be shut-off and the appliance shall be investigated and rectified
before it is used again. Tighten any leaking fittings, then turn on gas supply and recheck.
• If necessary, substitute gasket (according to EN 549 Class B2) or material used to guarantee
tightness (according to EN 751-1 Class I).
Leakage Test Point ① ② ③
38