Jocel JAT011893 Manual De Instrucciones página 37

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS
LIGHTING
Before ignite the appliance, perform "Leakage Testing" in a well-ventilated area (outdoor). At first
use and after every LPG cylinder substitution, appliance gas circuit must be purged of the inside
air before igniting! To do this, turn the control knob counter-clockwise to the ignition position and
push it holding for 1 minute before attempting ignition.
1. Make sure that LPG cylinder, full 4/5 its capacity, contains proper LPG Gas (refer to Technical
Data on page 2). Turn LPG cylinder valve in full "ON" position and close LPG compartment panel.
2. Make sure that burner control knob is in "OFF" position.
3. Push the control knob and keep pressing while turning counter-clockwise to the corresponding
low position (small flame). At the same time push the ignition button. Igniter will spark
automatically (it is possible to ignite the appliance even with proper lit long match, approaching
carefully the burner managing in the same way).
4. When the burner is lit in low position (small flame), stop pushing ignition button and keep the
control knob pressed but not over 15 seconds to heat the thermocouple (FSD); then release it
(first ignition take generally more time, because gas circuit is full of air).
5. If the burner does not keep lit, wait 1-2 minutes and then repeat steps 3 and 4.
6. Burner now is lit in Minimum position (small flame).
7. Adjust the heat input by turning the knob from the Minimum position (small flame) to the
Maximum position, as properly.
8. After lighting, turn knob from Minimum to Maximum (big flame) position and back, to check flame
stability.
37
loading