EN
Menu item
[Interval flush]
[Power-on flush]
[Dynamic flush]
[Hybrid mode]
[Flush time]
34
Description
Interval flush
• User-controlled: A flush is
actuated at the end of the [flush
interval], whereby the flush
interval is restarted with every
use. The flush time is
determined by the [flush time]
value.
• Interval-controlled: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. The flush time
is determined by the [flush time]
value.
• Difference flush: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. If flushes have
already been performed within
the [flush interval], the postflush
only makes up the difference in
[flush time].
[Flush time]
[Flush interval]
Activate power-on flush
A flush is actuated after switching
on the mains voltage.
Activate dynamic flush
The flush time is shortened if user
frequency is high.
Activate hybrid mode
The flush is not actuated during
use (waterless operation). A
periodic flush is actuated once the
delay time (time out) or interval
has elapsed → See the 'Select
flush mode' chapter for a detailed
description.
[Flush time] for hybrid mode
[Time out] for hybrid mode
[Interval] for hybrid mode
Set the flush time
Determines the duration of the
flush after one use.
Application
• To fill the trap in the
case of low user
frequencies
• To flush out standing
water in the pipe
(hygiene function – to
prevent stagnation)
–
–
• To perform central flush
actuation
• To confirm a function
• To reduce water
consumption in the
case of high user
frequencies (e.g. in
sports stadiums)
• To reduce the water
consumption
–
–
–
• To optimise the flushing
out of the urinal
ceramic, observe the
water consumption
Area
Factory
setting
[Off], [User-
controlled],
[Interval-
[User-
controlled],
controlled]
[Difference
flush]
1–200 s
5 s
1–168 h
24 h
On/Off
On
On/Off
On
[Off], [User-
controlled],
Off
[Interval-
controlled]
1–15 s
7 s
5–720 min
60 min
10–
1440 min
1440 min
1–15 s
7 s
2 / 3
90071995661314699 © 11-2022
970.650.00.0(01)