Menu item
Description
[EN]
[DE]
Empty pipe
The solenoid valve is opened
24
so that the pipe can be
[EmptyPipe]
drained. 2 short signal tones
[RohrLeer]
sound every minute. The
function switches off automat-
ically after 30 minutes.
Factory setting
25
All functions are reset to
[FactrySet]
factory settings. 3 short signal
[Werkseinst]
tones sound. The urinal flush
control is restarted.
Activate cleaning mode
A short signal tone sounds
26
every 4 s. The flush actuation
[CleanMode]
is suppressed for the [cleaning
[Reinigung]
time] (menu item 45). The
urinal flushes at the end of this
duration.
Programmes
Interval flush
• User-controlled: A flush is
actuated at the end of the
[flush interval] (menu item
44), whereby the flush
interval is restarted with
every use. The flush time is
determined by the [interval
30
flush flush time] (menu item
[IntFlush]
43) value.
[IntervSp]
• Interval-controlled: A flush is
actuated at the end of the
[flush interval] (menu item
44), regardless of the
number of uses. The flush
time is determined by the
[interval flush flush time]
(menu item 43) value.
Activate power-on flush
31
A flush is actuated after
[PowOnFlsh]
switching on the mains
[NetzEinSp]
voltage.
Activate dynamic flush
32
[DynFlush]
The flush time is shortened if
[DynamSpül]
user frequency is high.
90071995661314699 © 11-2022
970.650.00.0(01)
Application
• To carry out
maintenance work
• To carry out winter
emptying
• To remedy
malfunctions
• To clean the urinal
ceramic without the
water running
• To fill the urinal trap in
the case of low user
frequencies
• To flush out standing
water in the pipe
(hygiene function – to
prevent stagnation)
• To perform central flush
actuation
• To confirm a function
• To reduce water
consumption in the
case of high user
frequencies (e.g. in
sports stadiums)
Area
Factory setting
On = <OK>
–
Off = <OK>
Start = <OK>
–
Start = <OK>
–
[0] = Off
[1] = User-
controlled
User-controlled
[2] = Interval-
controlled
On = [ON]
On = [ON]
Off = [OFF]
On = [ON]
On = [ON]
Off = [OFF]
EN
2 / 4
29