Technical Specifications - BFT ALCOR UL Instrucciones De Uso

Central de mando
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "WARNINGS" leaflet and an "INSTRUCTION MANUAL".
These should both be read carefully as they provide important information
about safety, installation, operation and maintenance. This product complies
with the recognised technical standards and safety regulations. We declare
that this product is in conformity with the following Directives: CAN/CSA-
C22.2 No. 247-92 UL Std. No. 325
GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components
are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation
operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
INSTALL THE GATE OPERATOR ONLY WHEN:
The operator is appropriate for the construction of the gate and the
usage Class of the gate,
All exposed pinch points are eliminated or guarded,
The operator is intended for installation only on gates used for vehicles.
Pedestrians must supplied with a separate access opening,
The gate must be installed in a location so that enough clearance is
supplied between the gate and adjacent structures when opening and
closing to reduce the risk of entrapment. Swinging gates shall not open
into public access areas,
The gate must be properly installed and work freely in both directions
prior to the installation of the gate operator. Do not over-tighten the
operator clutch or presure relief valve to compensate for a damaged
gate.
FOR GATE OPENERS WITH HOLD-TO-RUN CONTROL:
The gate operator controls must be placed so that the user has full view
of the gate area when the gate is moving,
A sign with the message "WARNING" must be positioned near the
INSTALLATION MANUAL
controls. The characters for the writing should be at least 6.4 mm high.
The following statement should also be indicated: "Moving Gate Has the
Potential of Inflicting Injury or Death - Do Not Start Gate Unless Path is
Clear".
An automatic closing device (such as a timer, loop sensor, or similare
device) shall not be employed
No other activation device shall be connected.
Controls must be far enough from the gate so that the user is prevented from
coming in contact with the gate while operating the controls. controls
intended to be used to reset an operator after 2 sequential activations of the
entrapment protection device or devices must be located in the line-of-sight
of the gate. Outdoor or easly accesible controls shall have a security feature
to prevent unauthorized use.
All warnings signs and placards must be installed where visible in the area
of the gate.
FOR GATE OPENERS PROVIDED WITH SENSOR FOR CONTACT-
FREE DETECTION:
See instructions on the placement of non contact sensor for each type
of application,
Care shall be exercised to reduce the risk of nuisance tripping, such as
when a vheicle, trips the sensor while the gate is still moving, and
One or more non-contact sensor shall be located where the risk of
entrapment or obstruction exist, such as the perimeter reachable by a
moving gate.
FOR GATE OPENERS PROVIDED WITH CONTACT DETECTION
(RUBBER EDGE OR SIMILAR):
On or more contact sensor shall be located at the pinch point of a
vehicular vertical pivot gate.
A hardwired contact sensor shall be located and its wiring arranged so
that the communication between the sensor and the gate operator is not
subjected to mechanical damage.
A wireless contact sensor such as one that transimts radio frequency
(RF) signals the gate operator for entrapment protection functions shall
be located where the transimission of the signals are not obscrtucted or
impeded y building structure, natural landscaping or similar obstruction.
A wireless contact sensor shall function under the intended end-use
conditions.
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS: to reduce the risk of injury or death:
Read and follow all instructions.
Never let children operate or play with gate control. Keep the remote
control away from children.
Always keep people and objects away from the gate. NO ONE SHOULD
CROSS THE PATH OF THE MOVING GATE.
Test the gate operator montly. The gate MUST reverse on contact with
a rigid object activates the non-contact sensor. After adjusting the force
or the limit of travel, reset the gate operator. Failure to adjust and retest
the gate operator properly can increase the risk of injury or death.
Use the emergency realease only when the gate is not moving.
KEEP GATES PROPERLY MAINTAINED. Read the owners manual.
Have a qualified service person make repairs to gate hardware.
The entrance is for veichles only. Pedestrians must use separate
entrance.
Save these instructions.
1) GENERAL OUTLINE
ALCOR UL mod. control unit has been designed to be applied on swing
gates. It can control one or two controllers.

2) TECHNICAL SPECIFICATIONS

Power supply
Loadless absorption
Accessory output power
Max. absorbed power
Control panel dimensions
Case protection
Working temperature
(*) Special voltages on request.
3) TERMINAL BOARD CONNECTIONS (fig. 2)
Keep the low voltage connections definitely separated from the power
supply connections.
ENGLISH
: 120V~ ±10% 60Hz (*)
: 400 mA
: 24Vac 200 mA max
: 500W
: See fig. 1
: IP54
: -20 +55 °C
ALCOR UL - Ver.04 -
7

Hide quick links:

Tabla de contenido
loading

Tabla de contenido