Technical Specifications; Installation Safety; Preliminary Operations; Input And Output Functionality And Connections - BFT CSB Xtreme Instrucciones De Uso Y De Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

EN

3. TECHNICAL SPECIFICATIONS

- Power supply:......................................................230Vac ±10%, 50/60Hz (115Vac on request)
- Flashing light output:...............................................................................................230Vac; 40W max
- Accessory output:...........................................................................................24Vac; 24W - 1A max

4. INSTALLATION SAFETY

In order to reach the level of safety required by current regulations, follow these prescriptions carefully.
1) Make all connections in the terminal block after carefully reading the instructions given in this manual and observing the general
rules and technical standards concerning electrical systems installations.
2) Always fi t an omnipolar circuit breaker with a contact gap of at least 3 mm.
3) Install a diff erential circuit breaker with a threshold of 30 mA.
4) Check the eff ectiveness of the protective earth and connect to it all the parts of the automation fi tted with a terminal or grounding
cable.
5) Fit at least one external warning device, such as a traffi c light or fl ashing light, along with a warning or danger sign.
6) Fit all the safety devices required by the type of installation, taking into consideration the risks it on cause.
7) Separate keep power lines (1.5 mm

5. PRELIMINARY OPERATIONS

Barriers with standard booms are automatically selected. For special booms (barrier 35 only), before operating the automation,
make sure to have correctly selected the barrier/boom type as follows:
- Press and hold down buttons F and + for 5 seconds.
- Select the barrier/boom type using buttons +/-.
- Press together F and + to confi rm.
- Select the actual barrier/boom being used.
Are presented the following choices, depending on the type of INVERTER:
MAXIMA ULTRA 35 / MAXIMA ULTRA 68

MAXIMA ULTRA 68 (auto select)

MAXIMA ULTRA 35 (auto select)

Boom Carbon (ULTRA 35 only)
MAXIMA ULTRA 36

MAXIMA ULTRA 36 (auto select)

Boom Carbon
The Company is not liable for injury to people or animals or damage of things in case of wrong selection of the barrier.
Selecting wrong barrier/boom void warranty.

6. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS

230Vac 50/60Hz power supply.
Connect LINE and NEUTRAL wires as shown on the board. Use cable type H07RN-F 2x1.5+E min.
L
N
Connect the yellow/green EARTH wire of the power supply mains to the earth terminal of the appliance.
Output 230Vac, 40W max.
OUT
LAMP
OUT24
Output 24Vac, 1A max
24 Vac
OUT2
Programmable dry relay output, max. 500mA 24 Vac/dc (parameter  - level 2)
OUT3
Programmable dry relay output, max. 500mA 24 Vac/dc (parameter  - level 2)
Control unit
2
min. section) from the low-voltage signal lines (0.5 mm

Boom ATM 90° (ULTRA 35 only)

Boom ATM 180° (ULTRA 35 only)

Boom ARTICULATED

Xtreme DD4 (fail safe)
6.1
CONTROL UNIT POWER SUPPLY
J1
6.2
FLASHING LIGHT OUTPUT
J4
J5
6.3
OUTPUTS/ACCESSORIES POWER SUPPLY
- 20 -
2
min. section).
Tabla de contenido
loading

Tabla de contenido