BFT ALCOR UL Instrucciones De Uso página 8

Central de mando
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ENGLISH
M1A
Power supply 120V~ ±10% 60Hz (Neutral wire to terminal 1)
1-2
3
GND
4-5-6 M1 motor connection (terminal 4 common wire, terminals 3-5 motor
and capacitor operation).
1-5
Blinker connection 120V
7-8-9 M2r motor connection (terminal 7 common wire, terminals 6-8 motor
and capacitor operation).
1-8
Electric lock connection 120V mod. EBP.
M1B
10-11 Open-close push button and key selector (N.O.).
10-12 Stop button (N.O.). If not used, leave jumped.
10-13 Photocell or pneumatic edge input (N.C.). If not used, leave bridged.
10-14 Opening limit switch (N.C.). If not used, leave jumped.
10-15 Closing limit switch (N.C.). If not used, leave jumped.
16-17 24 Vac power supply output for photocell and additional devices.
18-19 Second radio channel output of the double-channel receiver board (N.O.)
20-21 Antenna input for radio-receiver board (21 braid - 20 signal).
CON1Radio-receiver board connector, 1-2 channels.
Fig. 7 shows a general wiring diagram.
4) LED (fig. 3)
The ALCOR UL control unit is provided with a series of self-diagnosis LEDs
which control all the functions.
The functions of the LEDs are the following:
LD1 Stop - goes off when a stop command is given.
(LD2 off, LD7 on) - Gate opening
(LD2 off, LD7 off) - Gate stop
(LD2 on, LD7 on) - Gate closing
LD3 Start - goes on when a start command is given.
LD4 Photocell - goes off when the photocells are not aligned or in the
presence of obstacles.
LD5 Opening limit switch - goes off when the opening limit switch is
operated.
LD6 Closing limit switch - goes off when the closing limit switch is
operated.
5) FUNCTIONING LOGIC
5.1) 4-step logic: (Dip-Fix IBL ON)
The following actions take place after a start command:
closed gate
: opens
opening
: stops and operates the TCA (Dip-Fix TCA ON)
open gate
: closes
closing
: stops (stops and does not operate the TCA)
after the stop
: opens
With Dip-Fix IBL ON, any start command given during opening has no
effect.
5.2) 2-step logic: (on request).
The following actions take place after a start command:
closed gate
: opens
opening
: stops and operated the TCA (Dip-Fix TCA ON)
open gate
: closes
closing
: opens
after the stop
: opens
6) DIP-FIX SELECTION (fig. 3)
TCA Automatic closing time TCA.
ON: Automatic closing on.
OFF: Automatic closing off.
IBL
Blocks impulses
ON: START commands are not accepted during the opening phase.
OFF: START commands are accepted during the opening phase.
FCH Photocells
ON: Photocells are only active in the closing phase. If an object is
detected by the photocells during the closing phase, the gate reverses
the current movement.
OFF: Photocells are active both in the closing and opening phase. If an
object is detected by the photocells on closing or opening, the gate
stops; once the object has been removed, the gate opens.
7) TRIMMER ADJUSTMENT (fig. 3)
TCA (Dip-Fix TCA ON)
It is used to set the automatic closing time, after which the gate closes
automatically (adjustable from 0 to 90 sec.).
TW
It is used to set the motor working time, after which the motor stop
(adjustable from 0 to 90 sec.). When using electrical limit switches, increase
8
- ALCOR UL - Ver.04
INSTALLATION MANUAL
the motor stopping time by a few seconds with respect to the leaf closing
time.
DELAY M2
It is used to set the delay closing time of the second motor (M2r).
8) ACCESSORIES
SPL (fig. 4)
Pre-heating optional board. Recommended for temperatures below -10°C.
ME (fig. 5)
Optional board used to connect a 12Vac electric lock.
SS (fig. 6)
Optional board signalling gate open. Operates only with electrical limit
switches.
EBP (fig. 2)
The EBP electric lock with continuous service can be connected directly to
terminals 1 and 7.

Hide quick links:

Tabla de contenido
loading

Tabla de contenido