5.2.3 Chisel positioning
CAUTION
Risk of injury! Loss of control over the chisel direction.
▶ Do not operate the tool when the selector switch is set to "Chisel
positioning". Turn the function selector switch until it engages in the
"Chiseling" position.
The chisel can be set to 24 different positions (in 15° increments). This
ensures that flat chisels and shaped chisels can always be set to the
optimum working position.
▶ Set the function selector switch to the
5.2.4 Chiseling
8
▶ Set the function selector switch to the
6
Care and maintenance
WARNING
Electric shock hazard! Attempting care and maintenance with the supply
cord connected to a power outlet can lead to severe injury and burns.
▶ Always unplug the supply cord before carrying out care and maintenance
tasks.
Care
•
Carefully remove stubborn dirt from the tool.
•
Clean the air vents carefully with a dry brush.
•
Use only a slightly damp cloth to clean the casing. Do not use cleaning
agents containing silicone as they can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may
lead to serious injuries including burns.
▶ Repairs to the electrical section of the tool or appliance may be carried
out only by trained electrical specialists.
•
Check all visible parts and controls for signs of damage at regular
intervals and make sure that they all function correctly.
•
Do not operate the product if signs of damage are found or if parts
malfunction. Have it repaired immediately by Hilti Service.
•
After cleaning and maintenance, fit all guards or protective devices and
check that they function correctly.
12
English
7
position.
position.
2244432