Parkside PKO 400 A1 Instrucciones De Utilización Y De Seguridad página 50

Idiomas disponibles
  • ES

Idiomas disponibles

Anleitung_LB5_4010413:_
GB/
MT
Please note that our equipment has not been
designed for use in commercial, trade or
industrial applications. Our warranty will be
voided if the equipment is used in commercial,
trade or industrial businesses or for equivalent
purposes.
5. Technical data
Mains connection:
Motor rating kW:
Operating mode:
Compressor speed min
-1
:
Operating pressure bar:
Pressure vessel capacity (in liters):
Theoretical intake capacity (l/min): approx. 400
Effective delivery rate at 7 bar: approx. 160l/min
Sound power level L
in dB:
WA
K
uncertainty:
WA
Protection type:
Weight of the unit in kg:
Oil (15W 40):
The product meets the requirements of EN
61000-3-11 and is subject to special
connection conditions. This means that use
of the product at any freely selectable
connection point is not allowed.
Given unfavorable conditions in the power
supply the product can cause the voltage to
fluctuate temporarily.
The product is exclusively intended for use
at connection points that have a continuous
current-carrying capacity of at least 100 A
per phase.
As the user, you are required to ensure, in
consultation with your electric power
company if necessary, that the connection
point at which you wish to operate the
product meets the specified requirements.
50
28.02.2011
13:52 Uhr
Seite 50
6. Before starting the equipment
Check the equipment for damage which
may have occurred in transit. Report any
damage immediately to the transport
company which was used to deliver the
compressor.
Install the compressor near the point of
consumption.
Avoid long air lines and supply lines
(extension cables).
230 V ~ 50 Hz
Make sure that the intake air is dry and
2.2 kW
dustfree.
S1
Do not install the compressor in a damp or
wet room.
2850
The compressor may only be used in
max. 8
suitable rooms (with good ventilation and an
50
ambient temperature from +5 °C to 40 °C).
There must be no dust, acids, vapors,
explosive gases or inflammable gases in the
room.
97
The compressor is designed to be used in
4 dB
dry rooms. It is prohibited to use the
compressor in areas where work is
IP20
conducted with sprayed water.
44
The oil level in the compressor pump has to
0.3 l
be checked before putting the equipment
into operation (see 9.4).
7. Assembly and starting
Important!
You must fully assemble the appliance
before using it for the first time!
You will require the following tools for assembly
and installation:
1 x open-ended wrench size 14 mm (not
included)
2 x open-ended wrench size 17 mm (not
included)
1 x open-ended wrench size 23 mm (not
included)
7.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.