▪ No flame during lighting.
AL 5
▪ The shutdown procedure is
NO IGN
activated.
▪ The flame goes out during
operation.
AL 6
▪ Occurs in case of pellet
NO PELLETS
level sensor intervention (if
present)
▪ Occurs in case of auger
duct temperature safety
AL 7
THERMOSTAT
thermostat intervention.
▪ The system is stopped.
▪ In the work phase, the
device detects a pressure
AL 8
lower than the vacuum
PRESSURE
SWITCH
switch calibration threshold.
▪ The system is stopped.
▪ Occurs when the unit has
exceeded 1800 hours
of operation or 2000 Kg
SERVICE
pellets since the previous
service.
EN
▪ The pellet hopper is empty.
▪ The heating element is
faulty, dirty or incorrectly
positioned.
▪ Incorrect pellet load setting.
▪ The pellet hopper is empty.
▪ The pellet feed gearmotor
is faulty or not powered.
▪ The gearmotor does not
load pellets.
▪ The safety thermostat has
detected a temperature
higher than the calibration
threshold due to
overheating of the lower
part of the hopper, blocking
the operation of the
gearmotor.
▪ The combustion chamber
is dirty.
▪ Fume duct obstructed.
▪ The fire door is not closed.
▪ The overpressure valves
are open/jammed.
▪ Faulty vacuum switch.
▪ Extraordinary maintenance
alert.
A73024050 - Rev 00 - 07/2023
▪ Check the presence of
pellets in the hopper.
▪ Check the lighting
procedures.
▪ Other reinstatement
operations must be carried
out by a Service Center.
▪ Check the presence of
pellets in the hopper.
▪ Check the feed of pellets.
▪ Other reinstatement
operations must be carried
out by a Service Center.
▪ Check the cause of
excessive overheating.
▪ Unblock the safety
thermostat with the reset
button.
▪ Check that the fume duct
and combustion chamber
are clean.
▪ Check the hermetic closure
of the door.
▪ Check closing of the
overpressure safety valve.
▪ Other reinstatement
operations must be carried
out by a Service Center.
▪ Extraordinary cleaning-
maintenance and
reinstatement operations
must be carried out by an
authorized service center.