Cointra MENSA Instrucciones De Uso, Instalación Y Mantenimiento página 158

Idiomas disponibles

Idiomas disponibles

11.3 INFORMATION FOR THE MANAGEMENT OF WASTE ELECTRICAL AND
ELECTRONIC EQUIPMENT CONTAINING BATTERIES AND ACCUMULATORS
This symbol, which appears on the product, on batteries or accumulators or on their packaging or
documentation, indicates that, at the end of their useful life, the product and any batteries or
accumulators must not be collected, recovered or disposed of together with household waste.
Improper management of waste electrical and electronic equipment, batteries or accumulators
can cause the release of dangerous substances contained in the products. In order to avoid any
damage to the environment or to health, the user is requested to separate this equipment, and/or the
batteries or accumulators, from other types of waste and take it to the municipal collection center.
It is possible to ask the distributor to collect the waste electrical and electronic equipment under the conditions and
according to the procedures established by Leg. Decree 49/2014.
Separate collection and proper treatment of electrical and electronic equipment, batteries and accumulators helps
the conservation of natural resources, respect for the environment and ensures the protection of health.
For further information on the collection centers for waste electrical and electronic equipment, batteries and
accumulators, contact the public Authorities competent for issuing permits.
12. TROUBLESHOOTING
Alarms are indicated by an acoustic signal (if activated) and a message on the control panel.
In case of an alarm shutdown the unit, eliminate the cause and restart the unit according to the normal procedure
described in this manual. Every alarm condition causes unit shutdown. The alarms which can appear on the control
panel, with causes and cures, are listed below:
Signaling
▪ Occurs in case of a power
AL 1
BLACKOUT
failure during operation
▪ Occurs in case of a fume
temperature probe fault.
AL 2
FUME PROBE
▪ The shutdown procedure is
activated.
▪ Alarm signaling occurs if
the fume probe detects a
temperature higher than
AL 3
FUME TEMP
280°C.
▪ The shutdown procedure is
activated.
▪ Occurs when the fume
exhaust fan is faulty.
AL 4
FUME-EXTRAC.
▪ The shutdown procedure is
activated.
158
Fault
Possible causes
▪ No power in unit installation
room.
▪ Probe fault.
▪ The probe is disconnected
from the board.
▪ Overheating due to use of
the unit for too long.
▪ The room air fan is faulty or
not powered.
▪ Excessive pellet load.
▪ The fume fan is blocked.
▪ The speed control sensor
is faulty.
▪ No power to the fume fan.
A73024050 - Rev 00 - 07/2023
MENSA
Cures
▪ When restarting, if the
Blackout period is less
than a preset time, the
unit restarts in WORK
mode, otherwise the alarm
intervenes and it switches
to the cooling phase.
▪ Other reinstatement
operations must be carried
out by a Service Center.
▪ Reinstatement operations
must be carried out by a
Service Center.
▪ Check room air fan
operation.
▪ Check and adjust the pellet
feed.
▪ Other reinstatement
operations must be carried
out by a Service Center.
▪ Reinstatement operations
must be carried out by a
Service Center.