Atlas Copco TEX 03PS Instrucciones De Seguridad Y De Funcionamiento página 15

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
TEX 03PS, 05P, 05P H/R, 05P R
Select the correct dimension and length for the
compressed air hose. For hose lengths up to 30
m (100 ft), a hose with a minimum internal
diameter of 19 mm (3/4 in.) must be used. If the
hose length is between 30 and 100 m (100 and
330 ft), a hose with a minimum internal diameter
of 25 mm (1 in.) must be used.
Methods to prevent freezing
Ice formation in the silencer can occur when the
ambient air temperature is 0–10°C (32-50 °F) and
the relative humidity is high.
The machine is designed to avoid the formation of
ice in the silencer. Despite this, under extreme
conditions ice can form in the silencer.
Take the following actions to further counteract the
risk of ice formation:
Use Atlas Copco Breaker and hammer AIR-OIL
as a lubricant. Breaker and hammer AIR-OIL
counteracts freezing.
Use a water separator.
Connecting a water separator
The length of the air hose between the compressor
and the water separator must be such that the water
vapor is cooled and condenses in the hose before
reaching the water separator.
If the ambient temperature is below 0 °C (32 °F) the
hose must be short enough to prevent the water from
freezing before reaching the water separator.
Lubrication
The lubricant is important for the machine's function
and has a great impact on the useful service life. If
there is no integrated lubricator, then connect a
separate lubricator to the air hose. To guarantee
good lubrication, the length of the air hose between
the separate lubricator and the pneumatic machine
should not exceed 3 meters.
Use a synthetic lubricant such as Atlas Copco
Breaker and hammer AIR-OIL or mineral oil with the
properties recommended in the table below.
Temperature
Lubricant
range (°C)
Breaker and
-30 to +50
hammer AIR-OIL
Mineral oil/Synthetic
+15 to +50
oil
Mineral oil/Synthetic
-20 to +15
oil
© 2015 Construction Tools PC AB | No. 9800 0975 90c | 2015-01-13
Original instructions
Insertion tool
The tip of the working tool can become hot and sharp
when used. Touching it can lead to burns and cuts.
NOTICE Never cool a hot insertion tool in water, it
can result in brittleness and early failure.
Selecting the right insertion tool
Selecting the right insertion tool is a precondition for
proper machine function. It is important to select
insertion tools of high quality to avoid unnecessary
machine damage.
The machine can be destroyed if you use an incorrect
insertion tool.
Recommended insertion tools are listed in the
machine's spare parts list.
Narrow chisel
Moil point
Wide bladed chisel
Using inserted tools that do not fulfil the criterias
mentioned below, will result in a longer time to
complete a task, and may result in higher levels of
vibration exposure. A worn tool will also cause
increased working time.
Viscosity
-
ISO VG 46–68
ISO VG 22–32
Safety and operating instructions
CAUTION Hot working tool
Never touch a hot or sharp working tool.
Wait until the working tool has cooled down before
carrying out maintenance work.
The narrow chisel is used for
demolition and cutting work in
concrete and other types of
hard materials.
The moil point is only used for
making holes in concrete and
other types of hard materials.
The wide bladed chisel is used
in soft materials, such as
asphalt and frozen ground.
WARNING Vibration hazard
Make sure that the inserted tool is well-maintained,
not worn out and of the proper size.
Always use a sharp tool in order to work efficiently.
15
loading

Este manual también es adecuado para:

Tex 05pTex 05p h/rTex 05p r