Elmo Rietschle Campo Profibus 2FC 1PB Serie Manual De Instrucciones página 29

© Gardner Denver Deutschland GmbH
Homologaciones, directivas y normas
All wiring terminals marked to indicate proper connections for the power supply,
load and control circuitry.
The tightening, torque to connect the motor terminals, is 26.55 lb/in (size A to C)
and 5.31 lb/in to connect the PTC (in all sizes).
Instruction for operator and servicing instructions on how to mount and con-
nect the products using the intended motor connection adapter, please see
Installing the drive controller integrated in the motor and Adapter plates in the
operating manual.
Use 75° C copper wires only.
Drives do not provide over temperature sensing.
For Mx 4 used in Canada: TRANSIENT SURGE SUPPRESSION SHALL BE INS-
TALLED ON THE LINE SIDE OF THIS EQUIPMENT AND SHALL BE RATED 277 V
(PHASE TO GROUND), 480 V (PHASE TO PHASE), SUITABLE FOR OVERVOLTA-
GE CATEGORY III, AND SHALL PROVIDE PROTECTION FOR A RATED IMPULSE
WITHSTAND VOLTAGE PEAK OF 2.5 kV
Maximum Surrounding Temperature (sandwich version):
Electronic
INV MA 2 0.37
INV MA 2 0.55
INV MA 2 0.75
INV MA 2 1.10
INV MA 4 0.55
INV MA 4 0.75
INV MA 4 1.10
INV MA 4 1.50
INV MB 4 2.2
INV MB 4 3.0
INV MB 4 4.0
INV MC 4 5.5
INV MC 4 7.5
INV MD 4 11.0
INV MD 4 15.0
INV MD 4 18.5
INV MD 4 22.0
Overall heatsink dimen-
sions
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(200x40x250) mm
(200x40x250) mm
(200x40x250) mm
(216x83x300) mm
(216x83x300) mm
to be defined
to be defined
to be defined
to be defined
29
/
34
5
Surroun-
Suffix
ding
50° C
Gx3
50° C
Gx3
50° C
Gx3
50° C
Gx3
65° C
Gx3
65° C
Gx3
65° C
Gx3
65° C
Gx3
60° C
Gx3
60° C
Gx3
60° C
Gx3
65° C
Gx3
65° C
Gx3
to be defi-
Gx3
ned
to be defi-
Gx3
ned
to be defi-
Gx3
ned
to be defi-
Gx3
ned
07.2014 · 610.00260.55.010
loading