Stihl TS 400 Cutquik Manual De Instrucciones página 36

Idiomas disponibles

Idiomas disponibles

1
2
3
1
Maintenance work on the main filter and
auxiliary filter should only be carried out
at the depot or service shop.
:
Remove screws (1)
:
Remove filter casing (2)
:
Pull main filter (3) out of filter casing
and check. It must be replaced if
soiled or damaged.
The auxiliary filter must always be
replaced together with the main
filter.
:
Set choke lever to g
:
Peel the auxiliary filter (4) away from
the bottom of the filter and check.
It must be replaced if damaged.
Ensure that dirt cannot enter the
intake area when removing the
auxiliary filter.
:
Clean the filter chamber and refit all
filter components
TS 400
:
Replace the filter cover
:
Retighten the locking nut
Filter system
4
The quality of the filter elements used is
particularly important on account of the
special conditions prevailing when using
a cut-off machine (extremely high dust
loads and high dynamic loads).
STIHL air filters have been specially
designed for use in cut-off machines and
therefore meet the special requirements
imposed with regard to their mechanical
design, the materials used and the
manufacturing quality.
:
Extremely uniform pore size, folds
and strength of the filter paper
:
High compression strength and
dimensional accuracy of the filter
cartridges
All the air filter components in this
machine are matched with one another
as regards filter capacity and air
permeability.
English / USA
Only original STIHL air filters should
therefore be used. The high quality
standard of these parts coupled with the
specified maintenance and service work
guarantees troublefree operation and a
long engine life.
The engine is not always optimally
protected against entrained dirt
when using filters which appear to fit
but are made by other
manufacturers. Warranty claims
cannot be accepted if the engine
parts wear down excessively or the
engine is damaged in such cases.
35