Faber STILO STIL24SSV Instrucciones De Instalación Información De Uso Y Cuidado página 15

Idiomas disponibles

Idiomas disponibles

Cleaning metal grease filters
The filters must be cleaned every 2 months
of operation, or more frequently for particu-
larly heavy usage, and can be washed in a
dishwasher.
• Remove the Filters one at a time, pushing
them towards the back of the unit and at the
same time pulling downward.
• Wash the Filters without bending them, and
leave them to dry completely before replac-
ing. (If the surface of the filter changes colour
as time goes by, this will have absolutely no
effect on the efficiency of the filter itself.)
• Replace, taking care to ensure that the
handle faces forwards.
• No water can be present in filters before
installing back in hood.
Replacing Activated Charcoal Filter
The filter is not washable and cannot be regener-
ated, and must be replaced approximately every 4
months of operation, or more frequently for particu-
larly heavy usage.
• Remove the Filters one at a time, pushing them
towards the back of the unit and at the same time
pulling downward.
• Remove the saturated charcoal filter by releasing
the fixing hooks.
• Fit the new filter and fasten it in its correct position.
• Replace, taking care to ensure that the handle
faces forwards.
• "When used in recirculation mode, to Reduce
the Risk of Fire and Shock use only conversion
kit Model FILTER 2".
Lighting Unit
• LED lights must be replaced by Faber factory authorized
service.
15
loading