Procedure:
Step 1: Unscrew the fixation screws A and B of the lamp system and carefully remove it from the
housing.
Step 2: If replacing the lamp, remove the old lamp from the lamp holder.
Step 3: Insert the lamp into the lamp holder.
Step 4: Replace the lamp system in the housing and tighten the fixation screws.
Step 5: Adjust the lamp as described under lamp adjustment.
Lamp adjustment
counterclockwise ¼-turn at a time the light is bright and evenly distributed.
Do not operate this device with opened cover!
36/104
The lampholder is aligned at the factory. Due
to differences between lamps, fine adjustment
may improve light performance.
Strike the lamp, open the shutter, set the
dimmer intensity onto 100 % and direct the
light towards a flat surface (wall). Center the
hot-spot (the brightest part of the beam) using
the 3 adjustment screws "1, 2, 3". Turn one
screw at a time to drag the hot-spot diagonally
across the projected image. If you cannot
detect a hot-spot, adjust the lamp until the
light is even.
To reduce a hot-spot, pull the lamp in by
turning all three screws "1, 2, 3" clockwise ¼-
turn at a time until the light is evenly
distributed.
If the light is brighter around the edge than it
is in the center, or if light output is low, the
lamp is too far back in the reflector. "Push" the
lamp out by turning the screws "1, 2, 3"
00026934.DOC, Version 1.6