Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
DMX-control-channels:
DMX-512-connection:
Flash-rate:
Colour-wheel:
Rotating gobo-wheel:
Outside diameter of the gobos:
Image diameter of the gobos:
Length of base:
Width of yoke:
Height (head horizontal):
Weight (net):
Maximum ambient temperature T
Maximum housing temperature T
Min.distance from flammable surfaces:
Min.distance to lighted object:
Fuse:
Accessory:
OSRAM 4ARXS HSD 97V/150W G-12 7000K 2000h
FUTURELIGHT CP-240 controller
FUTURELIGHT CP-512/64 controller 16bit
Wizard-512 USB DMX software + interface
Wizard-1024 USB DMX software + interface
Flightcase for 2xPHS-150/220+roll./brake
FUTURELIGHT DES-3 DMX-terminator 3-pin
Please note: Every information is subject to change without prior notice. 22.04.2008 ©
230 V AC, 50 Hz ~
285 W
10
3-pin XLR
10 Hz
8 dichroic filters and open
6 gobos and open
27 mm
23 mm
330 mm
320 mm
485 mm
13 kg
:
45° C
a
(steady state):
70° C
B
0.5 m
0.5 m
T 3.15 A, 250 V
No. 89101910
No. 51834265
No. 51834295
No. 51860102
No. 51860110
No. 51836855
No. 51834001
53/104