Campbell Hausfeld TL0517 Manual De Instrucciones De Operación página 7

Idiomas disponibles

Idiomas disponibles

Troubleshooting Chart (Continued)
Symptom
Moisture blowing out of tool 1.
Impact Mechanism Troubleshooting Guide
Symptom
Impacts slowly or will not
impact
Impacts rapidly but will not
remove bolts
Does not impact
Notes
Possible Cause(s)
Water in tank
2.
Water in the air lines/hoses
Possible Cause(s)
1.
Lack of lubrication
2.
Tool regulator set in wrong position
3.
In-line regulator or compressor
regulator set too low
1.
Worn impact mechanism
1.
Broken impact mechanism
Corrective Action
1. Drain tank. (See air compressor manual).
Oil tool and run until no water is evident.
Oil tool again and run 1-2 seconds
2. a. Install a water separator/filter.
NOTE: Separators only work properly when
the air passing through the separator is
cool. Locate the separator/filter as far as
possible from the compressor
b. Install an air dryer
c.
If the original separator will not
separate all the water from the air,
install a belt air filter
Corrective Action
1. Lubricate the air motor and the impact
mechanism. (See Lubrication section of
this manual)
2. Adjust the regulator on the tool to the
maximum setting
3. Adjust regulators in the air system
1. a. Replace worn impact mechanism
components
b. Return impact wrench to Authorized
Service Center for repair
1. a. Replace broken impact mechanism
components
b. Return impact wrench to an Authorized
Service Center for repair
7
TL0517
www.chpower.com
loading