Selco BOX RI 1000 Instrucciones De Uso página 23

Ocultar thumbs Ver también para BOX RI 1000:
Idiomas disponibles
  • ES

Idiomas disponibles

PROGRAMMABLE PARAMETERS:
GAS CYCLE: confirmation signal of gas cycle active.
0V = gas cycle inactive
24V= gas cycle active
SAFETY LIMIT WARNING: confirmation signal of safety limit no warning active.
SAFETY LIMIT ALARM: confirmation signal of no alarms.
3.1 Configuration digital inputs
In this manual, all instructions will be referred to:
"Configuration standard digital inputs"
3.1.1 Configuration standard digital inputs
0V =
0 Input opened or not connected (low state)
24V =
1 Input closed or powered (high state)
3.1.2 Configuration inverted digital inputs
0V =
1 Input closed (low state)
24V =
0 Input opened or powered (high state)
Consult the section "Set-up parameter 400" (Genesis ... repair manual)
0V= safety limit warning active
24V = safety limit warning inactive
0V = safety limit alarm active
24V = safety limit alarm inactive