Fulgor Milano FCHH 905 ID TS G DWK Instrucciones Para La Instalación Y Uso página 25

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Error codes are displayed by the 7-segment display with "E" or "ER" plus the error number.
Error message Description
"flash"
Permanent use of keys; Control unit
cuts off after 10 sec
Er 22
Defective Key evaluation.
Control unit cuts off after 3.5 – 7.5
sec.
Er20
Flash-failure
Er36
NTC value is not within its
specification (value < 200mV or >
4.9V; control unit cuts off
Er31
Configuration data incorrect
Er47
Communication error between TC
and induction
E2
Overheating of the induction coils
U400
Secondary voltage of the power unit
to high (primary > 300V). Control
unit cuts off after 1 sec releasing a
permanent tone.
E5
Error on filter board
E6
Error on power unit
E9
Coil temperature sensor defective
Possible error reason
Water or cooking utensils on the
glass above the control unit
Short-circuit or discontinuation in the
range of the key evaluation
µC- faulty
Short-circuit or cut-off at NTC
Configuration of induction necessary New Configuration
None or faulty communication!
Control unit is wrongly connected.
Troubleshooting
Cleaning of the operational surface
Exchange control unit
Exchange control unit
Exchange control unit
Ensure that connection cable is
plugged on correctly and functional.
Cooling down necessary
Connect to correct mains voltage
Exchange filter board
Exchange power unit
Exchange temperature sensore
EN
9
loading