a. Filter lifetime indicator
Status
More than 14 days
Less than 14 days
The �lter has reached the
end of life and should be
replaced immediately
b. Error indicator
- If the faucet is constantly turned on for 2 hours, the system will go into protection mode
and shut down. Meanwhile, the error indicator �ashes in red, and you will hear beeps.
Unplug the system, wait for 1 minute, and plug in again to shoot the trouble.
c. Auto-�ush
- The system �ushes automatically when it is powered up.
- The system �ushes automatically when it has been �ltering water continuously for 5
minutes.
- The system �ushes automatically when it is hasn't been �ltering water for 72 hours.
d. Flush button
You may manually �ush the system by pressing the �ush button when the system is in
standby mode. During the �ush, press the �ush button again to stop it.
e. Reset button
To reset the �lter lifetime, long press the reset button for 5 seconds. You will hear a beep,
and the indicator of CP �lter lifetime �ashes blue. Short press the reset button again to
select the �lter that needs to be reset.
When the indicator of the selected �lter �ashes, long-press the reset button for 3 seconds.
You will hear a beep, and the indicator will show constant blue light.
This means the �lter lifetime has been reset successfully.
Indicator
Constant blue light
(machine)
Constant white light
(faucet)
Flashing red light
(machine & faucet)
Constant red light
(machine & faucet)
10
Sound alert
N/A
There will be beeps whenever
the faucet is turned on,
reminding you to replace the �lter.
There will be beeps whenever
the faucet is turned on,
reminding you to replace the �lter.
loading