The working resistor thermostat must be set to 120 °C, while the safety
one to 180 °C. Said adjustments can be slightly modified following the
type of fuel and particular uses.
A - Safety thermostat (180° C).
B - Working thermostat (100°/120° C).
C - Stand-by thermostat (150° C).
he working resistor thermostat must be set to 120 °C, while the safety
one to 180 °C. Said adjustments can be slightly modified following the
type of fuel and particular uses.
A - Safety thermostat (180° C).
B - Working thermostat (100°/120° C).
C - Stand-by thermostat (150° C).
D - Fiding head thermostat (120° C).
For a correct burner ignition, carefully respect the
dimensions shown by the picture.
CLEANING AND MAINTENANCE OF FILTERS MOUNTED ON THE PREHEATER
REMOVING OF THE FILTER
1 - Switch-off the burner and make cold to leave.
2 - Take off oil thermometer bulb C.
3 - Loosen screw B and drain part of the fuel from the
heater, until the fuel level drop below the filter.
4 - Unscrew and pull out the stem filter A from its seat.
5 - Clean the filter and reassemble the parts as shown by
the picture, then fit it in its own seat.
It is advisable to replace all filter and valve gaskets
whenever they are removed.
Note that when the burner is working the heater has a
pressure of abt. 23 bar, and that it becomes very
dangerous to carry out said operations with the burner
running.
ADJUSTMENT OF FUEL THERMOSTATS
ADJUSTMENT OF FUEL THERMOSTATS (...D)
POSITION OF IGNITION ELECTRODES
420010284700 Maxflam 10.1/ D - 20.1/ D M100
3÷4 mm
- 19 -
EN
4 mm
2 mm
A
B
C
loading

Este manual también es adecuado para:

Maxflam d 10.1Maxflam 20.1Maxflam d 20.1