Genius SPRINT 07 Instrucciones De Uso página 14

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
24 Vdc CONTROL UNIT FOR SLIDING GATES
The SPRINT control unit was designed to control the operation of 24Vdc sliding gates.
Thanks to its built-in electronic clutch device and encoder management, it guarantees - if correctly installed - installation
conforming to the safety regulations in force.
Extremely simple programming of the main functions reduces installation time.
Thanks to the facility for connecting two buffer batteries (optional), any mains power cuts can be overcome. A
waterproof outdoor grade enclosure is available for housing the buffer batteries.
Supply voltage of transformer
Supply voltage of control unit
Absorbed power
Motor max. load
Accessories max load
Flashing lamp max load
Operating ambient temperature
Protective fuses
Operating logics
Opening / closing time
Pause time
Thrust force
Deceleration
Terminal board inputs
Radio receiver
Terminal board outputs
Board dimensions
Characteristics of 230V~ toroidal transformer
Characteristics of 115V~ toroidal transformer
Characteristics of optional batteries
Characteristics of outdoor enclosure
Different output values can be obtained on the 24V~ output depending on the mains voltage value. Before
start-up, always check the transformer output voltage. It must not exceed 26V~ for both power feed values of
230V~ and 115V~. Voltage must be measured load free, i.e. with the transformer powered and disconnected
from the board.
To ensure people's safety, all warnings and instructions in this booklet must be carefully observed. Incorrect
installation or incorrect use of the product could cause serious harm to people.
Make sure there is an adequate differential switch upstream of the system as specified by current safety standards,
and install an omnipolar thermal breaker on the electrical power mains.
• For the installation of power cables: use adequate rigid and/or flexible tubes, always separating low voltage
cables from cables at 230/115 V~. To prevent any interference whatever, use separate sheaths.
• Make sure that the mechanical closing and opening stops are installed.
To secure the various components inside of the airtight enclosure, refer to paragraph 14.
1. GENERAL CHARACTERISTICS
2. TECHNICAL SPECIFICATIONS
Automatic / Stepped automatic / Manual / Stepped manual
Through self-learning during programming
Through self-learning during programming
Opening and closing through self-learning
Power supply 22V~ / Batteries power supply / Total opening /
Pedestrian opening / Safety devices / Stop / Limit-switch at opening
/ Limit-switch at closing / Encoder / Antenna
Power supply: accessories 24 Vdc / Motors 24 Vdc /
prim. 230V~ - sec. 22V~ / 80VA / dimens. Ø105 x 40 mm.
prim. 115V~ - sec. 22V~ / 80VA / dimens. Ø105 x 40 mm.
3. PREPARATIONS
12
115/230 V~ (+6 -10%) - 50/60 Hz.
22 V~ (+6 -10%) - 50/60 Hz.
3 W
70 W
24Vdc 500mA
24Vdc 15W max.
-20°C +50°C
2
4 dip-switch adjustable levels
Integrated
Flashing lamp 24 Vdc
145 x 105 mm.
12V - 4 Ah / dimens. 90 x 70 x 108 mm.
306 x 225 x 130 mm. - IP55
loading

Este manual también es adecuado para:

Sprint 08