Make sure all electrical devices are switched off before
connecting them.
When plugging an appliance or an extension cord to the AC
sockets of the generator, the following aspects must be
observed:
▪ The appliances and extensions cords are in good
condition. Defective appliances and extension cords can
cause electric shocks;
▪ If an appliance begins to operate abnormally, slows
down or stops suddenly, switch it off immediately;
▪ The devices' power must not exceed the generator
output power. Never exceed the maximum power of the
inverter generator. Do not use the generator at its
maximum power for a period of more than half an hour.
Exceeding the time limit at full load will slowly overload the
generator and even though it will not trip the circuit
breaker, it will shorten the useful life of the generator.
Make sure the generator is grounded. When the electrical
device is grounded, so should the generator be.
To connect the appliances to the generator, proceed as
follows:
1. Start the generator;
2. Set the ESC switch to ON position;
3. Connect the AC schuko plug;
4. Make sure the AC pilot light (3B) is on;
5. You can connect the electrical device.
The ESC must be switched off to increase the engine
speed to the correct rpm. If the generator is
connected to several loads or electricity consumers,
remember to connect first the one with the highest current
and last the one with the lowest current.
1- Engine switch/ fuel shut off valve is in
Ignition system is off. Fuel circuit is off.
The engine will not start.
2 - Engine switch/ fuel shut off valve / Air intake in
position;
Ignition system is on. Fuel circuit is on. Air intake on.
The engine can start.
3 – Engine switch/ fuel shut off valve / Air intake is in
"CHOCKE" position;
Ignition system is on. Fuel circuit is on. No air intake.
The engine can start.
You don't need to set the 3 in 1 switch to CHOCKE
position to start a hot engine.
When the oil level falls below the minimum level, the oil
alert indicator light (1B) lights up and the engine stops
automatically.
If the engine stops or does not start, set the switch to
the "ON" position and pull the recoil starter. If the oil
alert indicator light flashes or a few seconds, the oil level is
insufficient. Add oil and start the engine.