8. Guide the display cable through the display
opening in the enclosure lid.
9. At the enclosure lid, tighten the M12x35 screw (TX55 or AF 8, torque: 13 Nm).
10. Connect display cable to display. Insert the plug and fasten it with 2 screws (Philips
screwdriver, torque 0.5 Nm). Insert the 2 screws on the cable holder (TX20, torque: 2 Nm).
11. Insert the display into the display opening.
12. Make sure that the seal of the display is smoothly flush with the mounting frame. There should
be no folds or wrinkles.
13. Place the provided clamping frame over the display
and tighten the two fastening screws (TX20, torque:
3 Nm).
14. Restore the DC power supply in the distribution board (DC-Combiner).
15. Switch on the AC miniature circuit breaker of all 3 line conductors.
16. Turn the DC load-break switch of the inverter to
position I.