Grundfos AMG Serie Instrucciones De Instalación Y Funcionamiento página 21

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 188
6. Mount the anchor bolts and fit the top fixation
bracket.
A
C
Top fixation
Pos. Description
A, B Bolts
C
Insulator
31
Hole for fastening a safety wire
7. Shorten the column profile (pos. 2 in fig.
AFG.xx.150/260, profile and support legs, back
view and AFG.xx.180-230, profile and support
legs) to the correct length to match the insulator
(pos. C in fig. Top fixation) at the top fixation
bracket. A gap of 5 to 10 mm between the collar
of the insulator and the column profile is optimal.
See fig. Top fixation.
8. Remove the insulator and the turnable metal part
from the top fixation bracket by removing the
centre screw (pos. A) and the two fixation screws
(pos. B). See fig. Top fixation.
9. Adapt the outside of the square insulator to the
inside of the column profile. The insulator must fit
tightly inside the column profile.
10. Fit the turnable metal part (now fitted on the top of
the column profile) to the already mounted top
fixation bracket. Tighten the three bolts (pos. A
and B in fig. Top fixation) in the desired position. It
is possible to adjust the angle in steps of 7.5 °.
11. Drill the holes for the mounting screws for the
bottom fixation plate in the bottom of the tank, and
insert the bolts. See fig. AFG.xx.150/260, profile
and support legs, back view.
12. Tighten the anchor bolts in the bottom fixation
plate.
13. Drill holes, mount and tighten the screws of the
front and back support legs as well.
31
B
14. Drill the holes for the mounting screws for the
crane foot in the concrete.
15. Mount the crane foot, then fit and tighten the
screws.
16. Mount the lifting wire on the motor bracket using
the shackle. See fig. Mounting of the lifting wire on
the motor bracket.
Mounting of the lifting wire on the motor bracket
17. Mount the top end of the safety wire to the hole
(pos. 31 in fig. Top fixation) of the top fixation
bracket using a shackle. The other end of the
safety wire ends in a shackle through which the
lifting wire must run.
Safety wire
15
21
loading

Este manual también es adecuado para:

Afg serie