Positioning sketch for mixers
Pos. Description
L
1
MIN
H
2
ABOVE
H
3
MIN
5.3.2 Flowmakers
Submerge the flowmaker as deeply as possible. See
fig. Positioning for flowmakers for the references of
distance.
The distance between the propeller tip and the
bottom of the tank (H
MIN
The distance from the propeller tip to the liquid
surface (H
) should be at least 0.75 times
ABOVE
the propeller diameter.
The distance between the propeller tip and the
wall behind the flowmaker (L
least twice the propeller diameter.
The sideways distance between the propeller tip
and the tank wall must be at least 0.5 metres.
If more flowmakers are installed in parallel, the
distance between their propellers must be larger
than half the propeller diameter.
The distance from a bend in the channel to the
propeller and from the propeller to aeration areas
should be at least the larger value of channel
width and water level.
12
) should be 50 cm.
) should be at
MIN
1
Positioning for flowmakers
Pos. Description
L
1
MIN
H
2
ABOVE
H
3
MIN
H
4
LIQUID
loading