Ditel JR-C Manual Tecnico página 57

Idiomas disponibles

Idiomas disponibles

AVAILABLE KEYBOARD FUNCTIONS
In addition to already known functions used to browse through the configuration menus and submenus, introduce
and/or modify existing values and parameters, the instrument provides some more added functions.
TARE, MAX/MIN and RESET functions
TARE function activates by pressing UP key (or by closing contact between pin 4 and pin 5 from CN2 input
connector, see page 9). Current display value is then stored (or added) in memory and the instrument shows (by
default) "0.00" or "0.0", depending on whether configured input range is 30mV or 300mV respectively. At the
same time, after the first digit (from the right), a point starts flashing indicating that the instrument has stored a
TARE value.
It is possible to tare instrument as many times as needed, as long as the accumulated value does not exceed the
limit value defined by the working range. Otherwise overflow indication "OuE" will be displayed. Stored tare value
remains in memory although power supply is removed.
This device detects and stores in memory maximum and minimum values reached by the input signal. This values
remain in memory although power supply is removed, as well. When pressing repeatedly SHIFT key, MAX/MIN
function shows saved maximum and minimum values in display since last RESET function activation.
In order to differentiate this values indication from a mode RUN indication, decimal point blinks during the time
these values are showed. The unit automatically switches back to RUN mode after 15 seconds have elapsed since
the last key press.
First SHIFT key pressing shows "MAH" in display followed by the maximum value, a second pressing now shows
"Min" followed by the minimum value and finally, a third pressing shows "run" to back again in an instant to RUN
mode.
MAX/MIN RESET function activates when visualizing maximum or minimum values SHIFT key is pressed for at
least 5 seconds. If maximum is the displayed value, current input signal value will replace the previous maximum
saved value. In the same way, current input signal will replace saved minimum value while is the minimum the
displayed value.
TARE RESET function activates by pressing UP key or maintaining remote contact closed for at least 3 seconds.
This is only possible in RUN mode. After that time, stored value will be added to the current display and erased
from memory and the flashing point will disappear.
Direct access to setpoints value
Pro
SEt1
00.00
SEt2
00.00
SERIE KOSMOS
If 2RE output option is installed, it is possible to access to setpoints value
configuration without having to enter main menu.
To access this submenu, from RUN mode and after ENTER key is pressed, simply
press UP key while "Pro" is displayed.
www.ditel.es
JR-C / JR20-C
57
loading

Este manual también es adecuado para:

Jr20-c