Fronius Selectiva 4.0 UL B1 Manual De Instrucciones página 69

Idiomas disponibles

Idiomas disponibles

Selectiva 4.0 C1
UL
Risk of fire.
Fire can cause serious injury and property damage.
Mains voltage (-10 % / +10 %)
Mains frequency
Mains fuse protection
Minimum mains lead cross section
Duty cycle
Safety class
EMC emission class
Dimensions l x w x h
Platform
Pollution degree
Degree of protection
Overvoltage category
Operating temperature
Storage temperature
Relative humidity
Maximum altitude above sea level
Mark of conformity
Product standard
1)
2)
3)
4)
Device-specific
data
2120 UL 120 V
2120 UL 240 V
4045 UL 120 V
4045 UL 240 V
CAUTION!
Use only on circuits that have 20 ampere auxiliary circuit protection in ac-
cordance with the National Electrical Code NFPA 70.
2)
3)
4)
The device may be operated on grids that are grounded at the neutral
point.
The leakage current to earth is less than 3.5 mA.
For indoor use only, must not be exposed to rain or snow.
At a high ambient temperature, a power reduction may occur (power de-
rating).
Max. AC
current
15.3 A
15.4 A
14.6 A
15.1 A
1)
1~ 120 V AC / 1~ 240 V AC
60 Hz
max. 20 A
AWG 12 (3.31 mm²)
100%
I (with ground conductor)
B
16.42 x 4.33 x 7.8 in.
(417 x 110 x 198 mm)
C1
2
IP21
II
-4 °F to 104 °F
(-20 °C to +40 °C)
-13 °F to 176 °F
(-25 °C to +80 °C)
Maximum 85%
6561 ft. (2000 m)
According to rating plate
UL1564, FCC Part 15 A & B
C22.2 No. 107.2-01
Max. AC
Nominal
power
voltage
2020 W
24 V
3320 W
1930 W
48 V
3250 W
Max.
charging
5)
current
Weight
120 A
8.7 kg
(19.18 lb.)
45 A
7.4 kg
(16.31 lb.)
69
loading

Este manual también es adecuado para:

Selectiva 4.0 ul c1