INSTALLATION & OPERATION
To Power
Male Pipe to Male Hose Adapter
(Suction)
Male Pipe to Male Hose Adapter
(Discharge)
Female Hose Connection
Figure 4 – Wall Mounted To Pressurized Service Line
To reduce friction losses to a minimum, inlet (suction) line
should be short and have as few elbows as possible.
Size the inlet according to the chart below:
THREADED
RECOMMENDED
AVE. GPM
INLET SIZE
INLET LINE SIZE
10
3/4" NPT
FP327 (01-15-23)
Service Line
Gate Valve or Hose Bibb
Male Pipe to Male Hose Adapter
High Pressure Hose with two
Female Connections
Gun Nozzle
Weeping Type ONLY
High Pressure Hose
1209 0894
RECOMMENDED
DISCHARGE LINE SIZE
1"
1"
An inlet strainer will prevent suspended debris from clogging
pump.
The internal running surfaces of the pump and seals require
water lubrication for good, consistent operation. Allowing pump
to run dry or with no flow will severely damage pump and seals.
Install a pressure gauge in pump inlet line.
Keep at least two pounds per square inch pressure (2 PSI) in inlet
line whenever pump is operating. If this is not possible, consult
customer service representative.
LUBRICATION
It is not necessary to lubricate pump or motor. The motor is
equipped with sealed ball bearings, lubricated for the life of
the bearing. The mechanical shaft seal in the pump is self-
lubricating and requires no adjust ment. Disassemble pump to
replace seal, see Maintenance.
OPERATION
Observe the following precautions when operating the pump:
1.
Keep the motor dry! Do not direct stream from pump
discharge onto the motor!
2.
RISK OF EXPLOSION. Do not ground to a gas
supply line. Do not run the pump with discharge shutoff,
as hose may burst or pump may be damaged due to high
temperatures.
3.
Do not use a standard trigger gun with this pump. Use only
trigger guns with an automatic weeping feature.
4.
Do not run pump dry; to do so may damage the seal.
5.
To avoid internal damage to pump, do not operate with
water temperature above 175 degrees F.