– RM 100 (Order No. 6.287-008) dis-
solves chalk and simple compounds of
chalk and detergents residues.
– RM 101 (Order No. 6.287-013) dis-
solves the deposits that cannot be dis-
solved using RM 100.
Fill a 20 litre container with 15 l water.
Add one litre of boiler decrusting agent.
Connect the water hose directly to the
pump and hang in the other free end
into the container.
Insert the connected spray pipe without
nozzle into the container.
Start the engine according to the oper-
ating instructions of the engine manu-
facturer.
Open the hand-spray gun and do not
close it during the decalcification pro-
cess.
Set the appliance switch to a working
temperature of 40 °C.
Let the appliance run till the working
temperature is reached.
Switch off the appliance and let it stand
for 20 minutes. The hand-spray gun
must remain opened.
Then pump out the machine until empty.
Note: As an anti-corrosion measure and for
neutralising the acid residue, we recom-
mend that you finally pump an alkaline so-
lution through the machine (for e.g. RM 81)
via the detergent tank.
Frost protection
ATTENTION
Risk of damage! Freezing water in the ap-
pliance can destroy parts of the appliance.
– Store the appliance in a heated room
during winter or empty it. During longer
breaks in operation, it is advisable to
pump in anti-frost agents into the appli-
ance.
– If it is not possible to store frost free,
shut down device.
Drain water:
Screw off water supply hose and high
pressure hose.
Screw off supply hose at boiler bottom
and drain heating spiral empty.
Operate device for max. 1 minute until
the pump and conduits are empty.
Flush appliance with anti-freeze agent:
Note: Observe handling instructions of the
anti-freeze agent manufacturer.
Fill anti-freeze agent of the trade into
swimmer container.
Switch on appliance (without heater) till
the appliance has been completely
rinsed.
A certain corrosion protection is achieved
with this as well.
Troubleshooting
DANGER
Risk of injury if the machine is left running
in an unattended state. Remove the spark
plug or disconnect the battery before work-
ing on the appliance.
Risk of burns! Do not touch hot silencers,
cylinders or radiator ribs.
Fuel indicator lamp glows
– Fuel tank empty
Refill.
Indicator lamp liquid softener glows
– Li uid softener tank is empty, due to
technical reasons a remainder stays in
the tank.
Refill.
– Electrodes in the tank are dirty
Clean the electrodes.
Appliance is not running
Follow operating instructions of the engine
manufacturer!
– Fuel tank empty.
Refill.
– HDS 1000 BE: Spark plug (motor) is
dirty/ defective
Clean or replace the spark plug.
– Safety thermostat at the high pressure
pump has switched off the appliance af-
ter long period of cycle operation.
Allow the appliance to cool down then
restart it. Refer section "Interrupting op-
eration".